Cells Per Unit: 6
Voltage Per Unit 12
Capacity: 120Ah@10hr-rate to 1.80V per cell @25oC
Weight: Approx. 34.0 Kg
Max. Discharge Current: 1200 A (5 sec)
Internal Resistance : Approx. 4.5 mΩ
Operating Temperature Range:
Discharge: -20oC~60
Charge: 0oC~50oC
Storage: -20oC~60oC
Normal Operating Temperature Range: 25oC±5oC
Float charging Voltage: 13.6 to 13.8 VDC/unit Average at 25oC
Recommended Maximum Charging Current Limit: 36 A
Equalization and Cycle Service : 14.6 to 14.8 VDC/unit Average at 25oC
Self Discharge: Valve Regul ated Lead Aci d(VRLA) bat teries can be stored for more than 6 mont hs at 25oC. Sel f-dischar ge ratio less than 3% per mont h at 25oC. Pleas e cha rge bat teries bef ore usi ng.
Terminal : Terminal F5/F12
Container Material: A.B.S. (UL94-HB) , Flammability resistance of UL94-V1 can be available upon request.