6-35VDC Smart BatteryProtect 12/24V 65A VSBP-65

6-35VDC Smart BatteryProtect 12/24V 65A

Protects the battery against excessive discharge and can be used as a system on/off switch - The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch.

12/24V auto ranging - The Smart BatteryProtect automatically detects system voltage one time only.

Bluetooth: programming made easy - When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled.

A special setting for Li-ion batteries - In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.

Ultra-low current consumption - This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.

Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.

Ignition proof - No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output - The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed load disconnect and delayed reconnect - The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

VictronConnect Compatible: VictronConnect lets you get live status information and configure any Victron products which either have Bluetooth built in, or are connected to a VE.Direct Bluetooth Smart Dongle , or a VE.Direct to USB Interface

Find out more about VictronConnect here , or download the App via these links

6-35VDC Smart BatteryProtect 12/24V 65A VSBP-65

6-35VDC Smart BatteryProtect 12/24V 65A

Protects the battery against excessive discharge and can be used as a system on/off switch - The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch.

12/24V auto ranging - The Smart BatteryProtect automatically detects system voltage one time only.

Bluetooth: programming made easy - When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled.

A special setting for Li-ion batteries - In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.

Ultra-low current consumption - This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.

Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.

Ignition proof - No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output - The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed load disconnect and delayed reconnect - The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

VictronConnect Compatible: VictronConnect lets you get live status information and configure any Victron products which either have Bluetooth built in, or are connected to a VE.Direct Bluetooth Smart Dongle , or a VE.Direct to USB Interface

Find out more about VictronConnect here , or download the App via these links

So you’ve done your shopping; just how long will it be till you can rock that new bit of tech?

Here are a few things to consider while you wait for your order:

  • We ship in business days. Monday - Friday, excluding national holidays.
  • Shipping starts from the date you received the “Your Order Has Shipped!” email.
  • The estimate above does not include processing time - we need 1-3 business days to process your order. This can vary depending on the time of the month and the warehouse's workload - If you need something processed faster than this please CALL US before placing your order!

HBPlus is an Australian company - we work with production and shipping partners all over the world to get your things to your doorstep, wherever that may be. Although the vast majority of our customers will get their orders by the day listed above, actual timeframes may vary from region to region.

So when do you contact HBPlus?

Take your date of order placement, add 2 business days plus the estimated shipping days and when that day rolls around and you still don't have it please get in contact with us. Even if your order hasn’t arrived by the listed date, it’s probably still on its way (and worth the wait).

How much is shipping?

You can view an estimate on the product page for how much an individual item costs to ship to your postcode. Once you’ve clicked through to Secure Checkout, you can enter your delivery address and choose a shipping method. Shipping costs are then calculated and you can select your preferred method. Shipping is then tacked on to your subtotal at the bottom of the page.

Can I track my order? 

We rely on a network of shipping partners and couriers as well as local postal services to get your order to your doorstep as soon as possible. Tracking is available once the order ships and the carrier collects the order. These details will be included on your orders page as well as on the shipping email we send you.

Where does my order ship from?

As one of Australias largest wholesalers, we have an Australian network of Warehouse's, 3PL DC's. In most cases your order will ship from our Main Victorian warehouse however depending on stock availability and/or location we may ship from a different location. At all times this will be to improve our service and delivery time frame to you.